Maintenance Kit for Queenaire QT Thunder (QTKIT300) — OEM Replacement Parts
The QTKIT300 is the annual maintenance kit for the Queenaire QT Thunder (QTT3F). It restores the unit to rated 300 mg/hr output and extends service life. One kit covers one annual service interval.
What’s Included
Replacement ceramic ozone plate(s) and electrode assembly components matched to the QT Thunder’s single-plate configuration. All OEM Queenaire parts. Installation follows the standard QT maintenance procedure: power off, housing access, plate swap, reassemble. No specialized tools required.
Specifications
| Spec | Value |
|---|---|
| Part Number | QTKIT300 |
| Compatible Unit | Queenaire QT Thunder (QTT3F) |
| Replacement Interval | Annually or every 500 operating hours |
| Post-Replacement Output | 300 mg/hr (restored to spec) |
Maintenance Schedule
Replace annually under standard use. In high-frequency commercial environments (daily operation), check output at 6 months. Signs of plate degradation: longer treatment times needed for equivalent results, reduced ozone smell in treatment areas, or visible corrosion on the plate surface. Keep a kit on hand to avoid gaps in service between jobs.